• No minimums, no surprises — we ship every order for free! We’ll get your filters out the door fast so you can enjoy clean air and water without paying extra.

  • Shop with confidence! If you're not completely satisfied with your purchase, you have up to one year to return it for a refund or exchange. We stand behind every filter we sell.

    Learn More

  • Every order is carefully packed and shipped by our team in Indiana. Your purchase helps support American jobs and hardworking families right here in the Midwest. Our AIRx Furnace / AC Filters and ClearChoice Fridge Filters are made in the USA.

Cart 0

We don't know what's in your water,
but we know there's nothing in your cart.

Menu

Aprilaire 4040 | Our#: 110960

Aprilaire #4040 Solenoid

Aprilaire 4040 | Our#: 110960

  •  Free Shipping & Free Returns
  •  100% Compatibility Guarantee
Replacement solenoid for Aprilaire humidifier. (24 volt) Humidifier includes inlet compression nut and washer.
  •  Free Shipping & Free Returns
  •  100% Compatibility Guarantee
Frequently Purchased Together

Product Details

 

Original Aprilaire #4040 replacement solenoid valve.  Note: Valve styles may vary.
 
  • 24 VAC
  • 2.3 Watts

Replacement solenoid value for Aprilaire Humidifier models 220, 224, 400, 440, 500, 550, 558, 560, 568, 600, 700, 760, 768.  The #4040 soleniod valve includes a new inline strainer (pre-inserted in inlet side of valve), and a compression nut & washer for the inlet side only.

Solenoid Valve Replacement Instructions

  1. For power units unplug electrical cord. For bypass units turn off power to furnace. Also turn the humidistat off.
  2. Shut off water supply at the saddle valve
  3. Disconnect inlet and outlet water compression nuts. Double wrench. Note, some water may drip on floor. Remove the orifice (which controls the water flow) from the plastic or copper tube and make sure there is no obstruction. If blocked clean or replace.
  4. Remove the wire nuts from the water solenoid valve wire connections. Set aside.
  5. Remove screws that secure valve to unit.
  6. Attach new valve with screws. Do not over-torque screws into plastic housing.
  7. Reconnect wires with wire nuts.
  8. For units with plastic feed tubes inspect for brittleness, hairline cracks, nicks or abrasions, etc.  Replace if necessary.
  9. Reconnect the water lines, double wrenching the compression nuts.
  10. Turn water back on and check system for leaks. Tighten compression nuts as necessary.
  11. Restore electrical service and activate furnace by turning up the thermostat.
  12. Turn up humidistat to verify operation of humidifier. Recheck for leaks. Turn down humidistat to make sure valve shuts off. Reset humidistat and thermostat to original levels.