CleanAlert FS-242-BWR | Our#: 177967

FILTERSCAN® Wireless Air Filter Monitor / Clog Detector

CleanAlert FS-242-BWR | Our#: 177967

  •  Fast Shipping & Free Returns
  •  100% Compatibility Guarantee
FILTERSCAN® Wireless Air Filter Monitor / Clog Detector
  •  Fast Shipping & Free Returns
  •  100% Compatibility Guarantee
Frequently Purchased Together

Product Details

FILTERSCAN® Wireless Air Filter Clog Detector - Model FS-242-BWR (battery-operated with wireless receiver)

A clogged air filter can reduce your indoor air quality (IAQ) and increase your energy bills.  Most importantly, a clogged filter can be the cause for very expensive repairs to your heating and cooling system.  A recent study notes that dirty filters are the primary cause of HVAC equipment failure.

The FILTERSCAN® monitor is installed and calibrated with a clean filter - and learns your system's peformance in a clean state by measuring the air pressure inside the HVAC system.  As your filter gets dirty - the pressure changes.  Once the pressure reaches a pre-determined level - the FILTERSCAN® monitor alerts the user that the filter needs to be changed or serviced.

How it works: When a clogged filter is detected - unit STATUS LED turns red and blinks/sounds an audible beep 5 times every 10 minutes until unit is reset (and clean filter is installed).  Alert data from the monitor is transmitted to a the wireless receiver.

Because the FS-242-BWR FILTERSCAN® is wireless - the monitor can be installed where HVAC equipment is located in attics, crawls, and other hard-to-reach places.

FEATURES AND BENEFITS:

  • Takes the guesswork out of changing your filter, and maintaining your filter system
  • Wireless technology transmits alerts from monitor to receiver in living space
  • Maximizes the efficiency of your HVAC system
  • Easy installation
  • Prevents costly repairs
  • FS-242-BWR is battery-operated (batteries included for monitor and receiver)

Technical Information:
Intended for continuous and automatic monitoring of the clogging of an air filter installed into a household or commercial forced air heating, air conditioning, or heat pump system.  Monitor is compatible with most air filters ranging in differential pressure drop from 0.10"wg to 4.0"wg and with single and multispeed blower HVAC systems, and most VAV (Variable Air Volume) systems.
FILTERSCAN® Air Filter Clog Detector, may be installed upstream, downstream, or differentially across the air filter, the best results will be found when installing downstream of the air filter (that is, between the air filter and the system blower fan, usually located at the return duct of the HVAC system).

SPECIFICATIONS:
Pressure Differential Range
-  0.1 to 4.0 in inches of water
Clog Filter Trigger Point -  1.5 to 2 times initial differential pressure (at the recommended setting on the SERVICE FILTER control)
Temperature Range - 32-122 F (0-50 C)
Operating  -40-257F (-40 - 125 C)
Storage Humidity -  80% RH, non-condensing
Power Requirements - 5.5 VDC at 25 mA Status LED on, 3 mA Transmitting, 60 uA Standby
Batteries, Monitor - (4) AA 2400 mAH
Batteries, Receiver - (2) AAA 1100 mAH
Battery Life - Approximately 1 year
Insertion Depth into Duct -  Does not extend into duct
Clogged Air Filter Alarm -  Red STATUS LED & 2 KHz Beeper alternating ON & OFF five times
Low Battery Alarm  - Yellow STATUS LED blinking approximately once per minute
Malfunction Alarm - Red STATUS LED continuously illuminated
Mounting 5 holes -  4 @ 7/64" and 1 @ 3/8"
Monitor Dimensions -  6" x 4.625" x 1.5"
Receiver Dimensions  - 2.75" x 3.75" x 1.0"
Wireless Frequency  - 418 MHz
Transmission Range -  Up to 100 feet, depending upon line-of-sight and obstacles
FCC Identification # AUPFS-242
Industry Canada # 10341A-FS242